Skip to main content

Model 312 Fixed Arbor Troubleshooting

Model 312 Fixed Arbor Troubleshooting

The Mereen-Johnson Model 312-DC is a fixed arbor straight line rip saw, and when it stops producing clean, consistent cuts, the cause almost always falls into one of a few categories: electrical and power issues, feed chain problems, or cut quality faults like bow cuts, tapered cuts, and general poor finish. This fixed arbor rip saw troubleshooting guide walks through each symptom in the order an experienced technician would diagnose it, with the probable causes and specific corrective steps.

Safety first: Always disconnect the main power supply before servicing the machine. Unevenly surfaced or bowed material can cause serious personal injury — confirm material condition before ripping.

For a complete downloadable reference, you can also view the full Model 312 Troubleshooting Guide PDF.

Motor Fails to Start

When the machine has power but the motor won’t start — or has no power at all — work through these causes in order. Most “dead machine” calls trace back to a tripped disconnect, blown fuse, open door interlock, or low lubrication/air condition rather than an actual component failure.

Probable Cause: No Power to the Saw

  • Main power disconnect may be off: Check the disconnect switch on the main Buss line
  • Fuses pulled or blown: Check the disconnect box; replace blown fuses with ones of the same size
  • Overload in the main starter cabinet: One or more starters may be tripped. The overloaded starter displays a white flag and its reset button pushes in with resistance. Push the manual reset. (Newer machines have one reset button; some state codes require automatic resets that reset once heater relays cool)
  • Control fuse (110V) blown: Replace the fuse in the starter cabinet (see your schematic for location and correct size)

Probable Cause: Arbor Access Door Interlock Not Made

Motors won’t start if the doors are ajar. Make sure access doors are properly closed and securely latched, and check whether the switches are loose.

Probable Cause: Low Oil or Air

  • Low oil in oil mist generators actuates the low-level cutout switch. Fill the system per the Oil Mist Lubrication notice on the machine
  • Low or no air pressure: Check that the compressed air supply line is properly connected

Feed Chains Do Not Run Smoothly

A rough-running feed chain almost always traces back to lubrication delivery problems or sawdust buildup. Always disconnect main power before servicing.

Probable Cause: Dry Feed Chain Pins and Vees

Extended feed chain pins and the bottom vees are dry — oil isn’t reaching the proper place on the chains. Check the oil mist generator.

Probable Cause: Improperly Positioned or Blocked Oil Mist Nozzles

Reposition the nozzles so one sprays on the bottom of the chain and the other on the extended pins. If nozzle ends are blocked, clean them and check alignment before start-up. If the oil mist generator is defective, replace it.

Probable Cause: Sawdust Buildup

  • Dip cam area: Remove and clean the dip cams
  • Feed sprocket teeth and chain center link: Remove several feed slats from the outfeed end near the feed sprockets, then inspect and clean the hardened dust buildup
  • Use compressed air to blow down the machine daily — a cleaning program dramatically reduces sawdust buildup

Probable Cause: Worn Dip Cams or Feed Chains

Dip cams can be switched side-for-side once. If your machine has Quad Life cams, both spacers beneath the cams may be removed and the cams reinstalled for use on both sides again (save the spacers). After that, install new cams. Replace or rebuild feed chains when the pins measure less than .450″ from the flat to the opposite side. Contact Mereen-Johnson Customer Service to order new dip cams.

Feed Chains Fail to Run

When the feed chains won’t run at all, the cause is usually a sheared shear pin, an open electronic shear pin contact, or a lubrication/air issue.

  • Worn roller chain or feed motor: Replace the worn roller chain, adjust if necessary, and lubricate with 10W non-detergent oil
  • Arbor motor not running: Start the arbor motor
  • Sheared shear pin in the drive coupling: Install a new shear pin per the Maintenance Section
  • Electronic shear pin has open contact: Reset per the Maintenance Section
  • Low oil in oil mist generator: Fill the system per the Oil Mist Lubrication Bulletin
  • Low air pressure at the oil generator: Air pressure should be 40–45 PSI while the machine is running

For complete shear pin and current sensor procedures, see our Model 312 maintenance guide.

Bow Cuts

When the machine produces bowed cuts (curved instead of straight rips), work through these causes:

  • Worn slat inserts: Replace them, and check the press roll adjustment to prevent material slippage in the bed
  • Bent aluminum feed slats: Install new Mereen-Johnson feed slats (call Customer Service for pricing)
  • Press rolls out of adjustment: Adjust or replace the springs; on air-loaded models, check the air regulator functions and settings
  • Infeed/outfeed conveyors influencing feeding: Realign and re-level — the infeed conveyor speed must match the rip saw feed speed exactly
  • Bowed material: Turn the concave side toward the guide so the material is forced against the guide as it feeds
  • Bent feed slats from excessive holddown or thick material: Ensure material is of uniform thickness

Tapered Cuts

Tapered cuts (one end wider than the other) usually trace back to unevenly surfaced material.

Material that’s unevenly surfaced side-to-side causes the high areas to hold the press rolls up off the thinner areas, making the thinner ripped pieces float sideways. Make sure material is evenly surfaced before ripping.

Danger: Unevenly surfaced material can cause serious personal injury. Confirm material condition before ripping.

Poor Quality of Cut

When overall cut quality has degraded, work through these causes:

  • Saw kerf cuts in the bed plate too wide: Install sharp tooling (contact Customer Service about new tooling) and/or install a new bed plate
  • Press roll to bed plate relationship incorrect: Refer to the Press Roll and Bed Plate sections of the manual
  • Arbor motor bearings failing: Install new motor bearings per the Arbor Motor Section

For complete cut quality diagnostics that apply across rip saws, see our straight line rip troubleshooting guide.

Outboard Bearing Assembly Seized to the Arbor Shaft Snout

This issue is specific to fixed arbor rip saws like the Model 312. When the outboard bearing assembly seizes to the snout of the arbor shaft, the inside diameter of the clamping sleeve or the outside diameter of the arbor shaft snout may be burred, damaged, or dirty.

To correct and prevent recurrence:

  1. Clean the ID and OD with emery cloth and/or a Scotch-Brite pad
  2. Remove any damage or contamination
  3. Apply a coating of anti-seize compound to the arbor shaft snout each time the outboard bearing assembly is removed
  4. Keep the surfaces clean and free from damage

Related Maintenance and Reference Guides

For complete coverage of your Model 312 fixed arbor rip saw, review these related resources:

Still Can’t Resolve the Issue?

If you’ve worked through the relevant section above and your Model 312 still isn’t producing consistent cuts, our factory service team can help. Mereen-Johnson technicians have hands-on experience with every Model 312 we’ve built and maintain the original manufacturing records and parts inventory — which means we can diagnose issues other service providers can’t and source exact-fit replacement parts.

Contact Mereen-Johnson service or call (612) 529-7791 to speak with a factory technician about your Model 312.